Structural Basics
A 7-day, diagram-rich structural course for reading and checking façade calculations. From force, moment and equilibrium to shear and moment diagrams, from section properties to stress and deflection, to bolt and bracket checks; all with worked examples on the same façade mullion. It prepares you for day 6 of the Façade Physics course and the site's Wind Load, Snow Load and Profile Section tools.
Before you start
Who is it for
Façade designers, draughtspeople, bid and project engineers; anyone who wants to read and check structural calculation reports.
What you need
- Basic arithmetic and powers are enough.
- A calculator or Excel.
Programme
| Day | Topic | What you learn | Time |
|---|---|---|---|
| Day 1 | Force and load path | Force and units, resultant, loads on the façade, load path from glass to slab | ~4 hours |
| Day 2 | Moment and equilibrium | Moment and eccentricity, equilibrium equations, support types, support reactions | ~4 hours |
| Day 3 | Internal forces | Shear and moment, diagrams, common beam formulas, transom and canopy examples | ~4 hours |
| Day 4 | Section properties | Area, centroid, moment of inertia, Steiner, section modulus, reading catalogues | ~4 hours |
| Day 5 | Stress and safety | Bending and shear stress, material strength, load and material factors, mullion strength | ~4 hours |
| Day 6 | Deflection | Deflection formula, façade deflection limits, mullion deflection check, options, snow load | ~4 hours |
| Day 7 | Connections and the whole calculation | Bolts, brackets, full mullion check, the site's tools | ~4 hours |
There is a checklist at the end of each day. As you tick items, your progress is saved in this browser. If you only study on weekday evenings, the programme takes about two weeks. This course teaches the logic of structures; in real projects calculations are done by a qualified engineer to EN 1990, 1991, 1993, 1999 and TS 498.
Force and load path
Goal
By the end of the day you will know what a force is, units, how forces add up, the types of load on a façade and how load is transferred from glass to the building (load path). About 4 hours.
About this course: It explains basic structural concepts with façade examples. It is the background for day 6 of the Façade Physics course (Turkish) and for understanding the site's Wind Load, Snow Load and Profile Section tools. In real projects calculations are done by a qualified engineer to the relevant standards (EN 1990, EN 1991, EN 1999, EN 1993, TS 498); this course does not replace that, but lets you read and check the calculation.
1. Force and units (1 hour)
A force is an action that pushes or pulls a body. It has a magnitude, a line of action and a direction; that is why it is drawn as an arrow (vector).
| Quantity | Unit | Façade example |
|---|---|---|
| Force | N, kN (1 kN = 1000 N) | Anchor reaction 3.24 kN |
| Distributed load (area) | kN/m² = kPa | Wind 1.2 kN/m² |
| Line load | kN/m = N/mm | Load on the mullion 1.8 kN/m |
| Moment | kNm, Nmm | 2.92 kNm in the mullion |
| Stress | N/mm² = MPa | 105 N/mm² in aluminium |
Mass and weight: 1 kg of mass weighs about 9.81 N. In practice 100 kg ≈ 1 kN.
Unit traps: there is a factor of 10⁶ between kN/m² and N/mm². Writing units on every line of a calculation is the best antidote to errors. 1 kN/m is exactly 1 N/mm.
2. Adding forces (45 min)
- Forces on the same line are added algebraically.
- Perpendicular forces: The resultant is found with Pythagoras. The resultant of a 3 kN horizontal and a 4 kN vertical force is √(3² + 4²) = 5 kN.
- Resolving into components: An inclined force is split into horizontal and vertical components: Fx = F·cos α, Fy = F·sin α.
3. Loads on the façade (1 hour)
| Load | Type | Source |
|---|---|---|
| Self-weight (G) | Permanent | Weight of glass, profiles, panels |
| Wind (W) | Variable | EN 1991-1-4; pressure and suction |
| Snow (S) | Variable | TS 498, EN 1991-1-3; canopy, sloped glass, eaves |
| Imposed load (Q) | Variable | Balustrade horizontal load, maintenance load |
| Temperature | Variable | Expansion, restraint |
| Earthquake (E) | Accidental / special | Turkish Building Earthquake Code |
Example: 8 + 6 mm insulating glass weighs about 14 × 2.5 = 35 kg/m². A 1.5 × 2.5 m pane weighs 3.75 × 35 ≈ 131 kg ≈ 1.29 kN.
4. Load path (1 hour)
The first question in structures is: Where does the load enter and where does it leave?
- Wind pushes on the glass.
- The glass passes the load at its edges to the transoms and mullions.
- Transoms pass the load to the mullions.
- Mullions pass the load to the brackets and anchors.
- Anchors pass the load to the slab, and the slab to the building structure.
Each link gives load to the next and takes load from the previous one. The weakest link of the chain determines the façade's capacity. A detail with a gap in the load path (e.g. no setting block to carry the glass weight) does not work whatever the calculation says.
End-of-day check (15 min)
Moment and equilibrium
Goal
By the end of the day you will know moment, the equilibrium equations, support types and how the support reactions of a beam are found. About 4 hours.
1. Moment (1 hour)
Moment = force × perpendicular distance to the line of the force. It is the turning effect of a force about a point.
Example: If the glass weight (1.29 kN) acts 100 mm outside the mullion face of the bracket, the moment in the mullion connection is:
M = F × e = 1.29 kN × 0.10 m ≈ 0.13 kNm
That is why eccentricity matters on façades: the closer you carry heavy glass to the mullion axis, the smaller the moment in the connection.
2. Equilibrium (1 hour)
A body at rest is in equilibrium. In the plane three equations are written:
ΣFx = 0 sum of horizontal forces is zero
ΣFy = 0 sum of vertical forces is zero
ΣM = 0 sum of moments about any point is zero
Unknown support reactions are found with these three equations. Choosing a point through which an unknown force passes for taking moments removes that force from the equation and makes things easier.
3. Supports (1 hour)
| Support | Restrains | Reactions | On the façade |
|---|---|---|---|
| Roller (sliding) | One direction | 1 force | Bottom (sliding) connection of the mullion, free vertically |
| Pinned (hinge) | Two directions | 2 forces | Top (hanging) connection of the mullion |
| Fixed (built-in) | Two directions + rotation | 2 forces + 1 moment | Cantilever canopy beam, steel cast into concrete |
One end of the mullion is pinned and the other a roller so it can expand and contract with temperature (Façade Design Basics, day 4). Structurally this means a simple beam.
4. Support reactions (45 min)
Example: mullion. Span L = 3.6 m, wind on the mullion q = 1.8 kN/m (1.2 kN/m² × 1.5 m module).
Total load Q = q × L = 1.8 × 3.6 = 6.48 kN
Symmetry RA = RB = Q / 2 = 3.24 kN
Check (ΣM_A = 0): RB × 3.6 = 6.48 × 1.8 → RB = 3.24 kN ✓
Each anchor takes 3.24 kN of horizontal load. This is the input for bracket and anchor selection.
Exercise: If an extra 1 kN point load (e.g. a sun shade) acts 1.2 m below the top support of the same mullion, what are the support reactions? (Answer: RA = 3.24 + 1 × 2.4/3.6 = 3.91 kN; RB = 3.24 + 1 × 1.2/3.6 = 3.57 kN.)
End-of-day check (15 min)
Internal forces
Goal
By the end of the day you will know the shear force and bending moment inside a beam, their diagrams and common beam formulas. About 4 hours.
1. Internal forces (1 hour)
Cut the beam in two with an imaginary section: for each part to stay in equilibrium there must be two internal forces at the section:
- Shear force (V): The force trying to slide the section in the perpendicular direction.
- Bending moment (M): The moment trying to rotate the section and bend the beam.
V and M are different at every point of the beam. Their graphs along the beam are called the shear force diagram and the bending moment diagram.
2. Simple beam, distributed load (1 hour)
Shear V(x) = q × (L/2 − x) largest at the ends: V = q × L / 2
Moment M(x) = q × x × (L − x) / 2 largest at mid-span: M = q × L² / 8
Mullion example: q = 1.8 kN/m, L = 3.6 m
V_max = 1.8 × 3.6 / 2 = 3.24 kN (at the supports)
M_max = 1.8 × 3.6² / 8 = 2.92 kNm (at mid-span)
Rule: Where the shear force is zero, the moment is largest.
3. Common formulas (1.5 hours)
| Case | Max moment | Max shear | Max deflection |
|---|---|---|---|
| Simple beam, distributed q | qL²/8 | qL/2 | 5qL⁴ / (384EI) |
| Simple beam, point load P at mid-span | PL/4 | P/2 | PL³ / (48EI) |
| Cantilever, distributed q | qL²/2 | qL | qL⁴ / (8EI) |
| Cantilever, point load P at tip | PL | P | PL³ / (3EI) |
| Simple beam, two equal P at distance a from the ends | P·a | P | (day 5) |
Example 1 — transom, glass weight: a 1.29 kN pane sits on two setting blocks, each a = 150 mm in from the transom end: P = 0.64 kN.
M = P × a = 0.64 × 0.15 ≈ 0.10 kNm (about the transom's weak axis)
Example 2 — cantilever canopy beam: L = 1.5 m, snow s = 0.6 kN/m², beam spacing 1.2 m → q = 0.72 kN/m.
M = q × L² / 2 = 0.72 × 1.5² / 2 = 0.81 kNm (at the fixed end)
4. Continuous beam, intuition (15 min)
A mullion continuous over two spans (continuous beam) has a smaller span moment and deflection than a simple beam of the same span; but a moment of opposite sign forms at the intermediate support. That is why the mullion splice is usually placed near the support, where the moment is small.
End-of-day check (15 min)
Section properties
Goal
By the end of the day you will be able to calculate the area, centroid, moment of inertia and section modulus of a section and read the values in profile catalogues. About 4 hours.
1. Area and centroid (45 min)
- Area (A): The material area of the section. Weight = A × length × density (aluminium ≈ 2.7 g/cm³, steel ≈ 7.85 g/cm³).
- Centroid: The "balance point" of the section. In symmetric sections it lies on the axis of symmetry. In a composite section: ȳ = Σ(Ai × yi) / ΣAi.
2. Moment of inertia (1.5 hours)
The moment of inertia (I) shows the section's stiffness against bending. Its unit is mm⁴ or cm⁴ (1 cm⁴ = 10⁴ mm⁴).
Rectangle (b width, h depth): I = b × h³ / 12
h cubed! Doubling the depth makes the stiffness eight times larger. That is why mullions are deep in the wind direction.
Box section: Subtract the inner void from the outer rectangle.
Example: 50 × 150 × 3 mm box mullion (h = 150 mm in the wind direction)
I = (50 × 150³ − 44 × 144³) / 12
= (168 750 000 − 131 383 296) / 12 ≈ 3 113 900 mm⁴ ≈ 311 cm⁴
A = 50 × 150 − 44 × 144 = 1 164 mm² → weight ≈ 1 164 × 2.7 / 1000 ≈ 3.1 kg/m
3. Steiner's theorem (45 min)
To find the moment of inertia of a part about an axis that does not pass through its own centroid:
I = I_own + A × d²
Example: a 100 × 10 mm flange, d = 50 mm from the axis:
I_own = 100 × 10³ / 12 ≈ 8 333 mm⁴
A × d² = 1 000 × 50² = 2 500 000 mm⁴
I ≈ 2 508 000 mm⁴ ≈ 251 cm⁴
Almost all of the contribution comes from A × d²: putting material far from the axis is the most efficient way. This is the logic of I-sections and deep box mullions.
4. Section modulus (45 min)
The section modulus (W) is used to calculate the section's bending strength:
W = I / c c: distance of the extreme fibre from the neutral axis
For the 50 × 150 × 3 mullion c = 75 mm:
W = 3 113 900 / 75 ≈ 41 500 mm³ ≈ 41.5 cm³
Reading catalogues: Profile catalogues give Ix, Iy, Wx, Wy. Check which axis is in the wind direction. In a mullion, wind usually bends about the strong axis. You can calculate values for standard sections with the site's Profile Section tool.
End-of-day check (15 min)
Stress and safety
Goal
By the end of the day you will be able to calculate bending and shear stress, know material strength, partial safety factors and load combinations, and check the strength of a mullion. About 4 hours.
1. Bending stress (1 hour)
In a bending beam one side is compressed and the other stretched; in between is the neutral axis where stress is zero. Stress increases with distance from the neutral axis and is largest at the extreme fibres:
σ = M / W
2. Shear stress (30 min)
Shear force is carried mainly by the webs of the section (the walls in the wind direction). Roughly:
τ ≈ V / A_web
Shear stress is usually small in façade mullions. It can matter in short, heavily loaded elements (brackets, cantilevers).
3. Material strength (45 min)
| Material | Modulus of elasticity E | Yield (example) |
|---|---|---|
| Aluminium EN AW-6063 T6 | 70 000 N/mm² | f0.2 ≈ 160 N/mm² |
| Aluminium EN AW-6060 T66 | 70 000 N/mm² | f0.2 ≈ 150 N/mm² |
| Structural steel S235 | 210 000 N/mm² | fy = 235 N/mm² |
| Structural steel S355 | 210 000 N/mm² | fy = 355 N/mm² |
Aluminium values vary with section thickness and heat treatment; in projects the tables in EN 1999-1-1 are used. The strength of aluminium drops considerably in welded zones.
4. Safety: load and material factors (1 hour)
In the Eurocode approach safety is provided from two sides:
- Loads are increased: Design load = characteristic load × γF. Typical values: 1.35 for permanent load, 1.5 for variable load.
- Strength is reduced: Design strength = characteristic strength / γM. Typical γM1 = 1.1 for aluminium; 1.0 for steel.
Load combination (ultimate limit state, basic form):
1.35 × G + 1.5 × Q_leading + 1.5 × ψ0 × Q_other
For example, if wind and snow act together one is leading and the other is reduced by the ψ0 factor. Factors are taken from EN 1990 and its national annex. Deflection is checked with unfactored (characteristic) load (day 6).
5. Mullion strength check (45 min)
Characteristic moment M_k = 2.92 kNm (day 3)
Design moment M_Ed = 1.5 × 2.92 = 4.37 kNm
Section W = 41.5 cm³ (day 4, 50 × 150 × 3)
Stress σ = 4.37 × 10⁶ / 41 500 ≈ 105 N/mm²
Design strength f_d = 160 / 1.1 ≈ 145 N/mm²
Utilisation 105 / 145 ≈ 0.73 → strength SUFFICIENT
Shear check: V_Ed = 1.5 × 3.24 = 4.86 kN, two webs 2 × 3 × 144 = 864 mm² → τ ≈ 5.6 N/mm², very small.
The mullion is sufficient in strength. But it is not finished yet: deflection (day 6).
End-of-day check (15 min)
Deflection
Goal
By the end of the day you will know what deflection is, the deflection limits on façades, the difference between stiffness and strength and why deflection usually governs on façades. About 4 hours.
1. Deflection (1 hour)
Deflection (δ) is the displacement of a beam as it bends under load. Simple beam, distributed load:
δ = 5 × q × L⁴ / (384 × E × I)
- L⁴: Increasing the span by 10% increases deflection by about 46%.
- E: The stiffness of the material. Steel's E is about 3 times that of aluminium.
- I: The stiffness of the section (day 4).
2. Deflection limits on façades (45 min)
Common limit for curtain wall framing members (EN 13830 and EN 13116):
| Span L | Limit |
|---|---|
| L ≤ 3 m | L / 200 |
| 3 m < L < 7.5 m | 5 mm + L / 300 |
| L ≥ 7.5 m | L / 250 |
There may also be limits required by the glass manufacturer at the glass edge support. Deflection is checked with characteristic load (unfactored).
3. Mullion deflection check (1 hour)
q = 1.8 N/mm, L = 3600 mm, E = 70 000 N/mm², I = 3 113 900 mm⁴ (50 × 150 × 3)
δ = 5 × 1.8 × 3600⁴ / (384 × 70 000 × 3 113 900) ≈ 18.1 mm
Limit = 5 + 3600 / 300 = 17 mm
18.1 > 17 → deflection NOT SUFFICIENT
The same mullion was comfortable in strength with 73% utilisation (day 5), but it fails in deflection. Required moment of inertia:
I_required = 5 × 1.8 × 3600⁴ / (384 × 70 000 × 17) ≈ 331 cm⁴
4. Options (45 min)
| Option | Result |
|---|---|
| Deeper profile: 60 × 180 × 3 (I ≈ 545 cm⁴) | δ ≈ 10.3 mm ✓ |
| Steel reinforcement in the same profile | Stiffness increases; weight and thermal mismatch need attention |
| Steel profile of the same size (E three times) | δ ≈ 6.0 mm ✓, but heavy and needs corrosion protection |
| Intermediate anchor (shortening the span) | L⁴ effect: the strongest option, but an extra connection on the building side |
Lesson: Because E is low in aluminium, deflection usually governs façade mullions. First find the required I from deflection, then check strength.
5. Snow load and sloped glass (15 min)
On canopies and sloped glass snow loads in addition to wind: s = μ × sk (shape coefficient × ground snow load). On a canopy next to a high wall snow can drift and the load can increase several times. The site's Snow Load tool does this calculation to TS 498 and EN 1991-1-3. Use the load you find with the cantilever formulas of day 3.
End-of-day check (15 min)
Connections and the whole calculation
Goal
On the last day you learn the basic checks of connections (bolts, brackets) and do a full structural check of a mullion. Then you connect to day 6 of Façade Physics and the site's calculation tools. About 4 hours.
1. Bolts (1 hour)
A bolt on a façade is stressed in three ways:
- Shear: The connected plates try to cut the bolt shank like scissors.
- Bearing: The bolt crushes the thin material at the hole edge. In thin aluminium walls this usually governs.
- Tension: Suction load tries to open the connection.
Edge distances: There must be enough material between the hole and the edge (typically e1 ≥ 1.2 d0 or more; values from the standard). A hole too close to the edge tears the plate.
2. Bracket (1 hour)
The 3.24 kN horizontal load at the mullion connection creates a moment in the bracket arm:
Design load P_Ed = 1.5 × 3.24 = 4.86 kN
Lever arm e = 80 mm (distance of the load from the bracket root)
Moment M_Ed = 4.86 × 0.08 ≈ 0.39 kNm
Plate 150 × 10 W = 150 × 10² / 6 = 2 500 mm³
Stress σ = 0.39 × 10⁶ / 2 500 ≈ 156 N/mm²
S235 steel f_d = 235 / 1.0 = 235 N/mm² → utilisation ≈ 0.66
The bracket is also checked for the capacity of the anchor in concrete (anchor manufacturer's software or approved values) and for the welds.
3. Mullion: start to finish (1.5 hours)
1. Load w = 1.2 kN/m² (wind, characteristic; from the Wind Load tool)
2. Load path q = w × b = 1.2 × 1.5 = 1.8 kN/m
3. Statics simple beam, L = 3.6 m
4. Forces M = qL²/8 = 2.92 kNm ; V = qL/2 = 3.24 kN
5. Deflection I_required ≥ 331 cm⁴ → choose 60 × 180 × 3 (I ≈ 545 cm⁴), δ ≈ 10.3 mm ✓
6. Strength W = 545/9 ≈ 60.6 cm³ → σ = 4.37 × 10⁶ / 60 600 ≈ 72 N/mm² ≤ 145 ✓
7. Support each anchor 3.24 kN (characteristic), 4.86 kN (design) → bracket and anchor
8. Other glass weight (transom), thermal movement, earthquake drift
This flow is the basis of day 6 of the Façade Physics course (Turkish). There you will see the same mullion together with how the wind load is found and the structural silicone calculation.
4. Tools on the site (15 min)
| Tool | What it gives | In this course |
|---|---|---|
| Wind Load | qp and wind load of façade zones | Step 1: w |
| Snow Load | Snow load on canopies, eaves, sloped glass | Cantilever canopy |
| Profile Section | Section properties, stress and deflection | Days 4-6 |
| Glass Weight | Glass weight | Self-weight |
5. Final word (15 min)
In the end structures come down to four questions: What is the load? Where does it go? Will the element bend too much (deflection)? Will it break (strength)? This course taught you to ask these questions and to check the calculation. In projects the final word belongs to the qualified engineer calculating to the relevant standards.