- Keep Ug low (winter heat loss) and choose g by orientation and climate (summer heat gain).
- Aim for a high Tv for daylight and a selectivity Tv/g ≥ 1.8 for efficiency.
- For sound: asymmetric thicknesses, a wider cavity and laminated glass with acoustic PVB.
- Laminated glass where safety is needed, heat-strengthened glass where there is a thermal breakage risk.
1. Heat: Ug
The heat passing through one square metre of glass for a 1 K temperature difference (W/m²K, EN 673). A low-E, argon-filled double glazed unit gives about 1.0–1.1; triple glazing 0.5–0.7. The value of the whole window, Uw, is calculated with the frame (Uf) and the glass edge thermal bridge (ψ).
2. Sun: g and Tv
g (solar factor) is the share of incoming solar energy that passes inside. On south and west façades of highly glazed offices 0.25–0.40 is typical; in housing, higher values may be preferred to benefit from winter sun. Tv is the share of daylight transmitted; below 0.50 the interior can feel dark. The ratio of the two is selectivity: less heat for the same daylight.
3. Sound: Rw
The weighted sound reduction index (dB) is given according to EN ISO 717-1. More mass and two panes of different thickness reduce resonance; laminated glass with an acoustic PVB interlayer makes a 3–5 dB difference. For traffic noise, Rw+Ctr is the more relevant value.
| Make-up | Typical Rw |
|---|---|
| 4/16/4 | ~30 dB |
| 8/16/6 | ~35 dB |
| 8/16/44.2 | ~39 dB |
| 10/20/44.2 acoustic | ~44 dB |
4. Glass types
| Type | When? |
|---|---|
| Float (annealed) | Unprocessed glass; breaks into large sharp pieces. Inside laminates or in low-risk locations. |
| Heat strengthened | About twice the strength of float; large pieces remain when broken. For dark or partly shaded glass with thermal breakage risk, inside laminates. |
| Toughened (tempered) | 4–5 times the strength of float; breaks into small fragments. Doors, low-level zones, thermal stress. A heat soak test is recommended against nickel sulphide risk. |
| Laminated | PVB/SGP between two panes; fragments stay on the interlayer when broken. Balustrades, sloped glazing, overhead glass, safety and sound. |
5. Thickness and weight
Thickness is calculated from wind load, pane size and support type (EN 16612, DIN 18008). Each millimetre of glass weighs 2.5 kg/m²; an 8/16/44.2 double glazed unit weighs about 42 kg/m², which governs setting blocks and installation equipment.
This guide is for education and preliminary information only; regulations, standards and values may change. Consult a qualified engineer before making decisions. If you spot an error, let me know. · All guides