| Capped (pressure plate) | Structural silicone | |
|---|---|---|
| Appearance | Horizontal and vertical cap lines outside | Flush glass surface, only joint lines |
| Glass retention | Mechanical: pressure plate and screws | Bonded with structural silicone; dead load on setting blocks |
| Fabrication | Mostly site assembly | Frames are siliconed in the workshop; curing time needed |
| Glass replacement | Easy, the cap is removed from outside | The frame is removed and re-siliconed |
| Quality control | Relatively simple | Silicone compatibility test, adhesion tests, record keeping |
| Cost | More economical | Higher (silicone, testing, labour) |
| Thermal insulation | Thermal break at the pressure plate | Load-bearing profile behind the glass; good Uf values |
When to choose capped?
When the budget is limited, the building is low to mid-rise, a fast and flexible site solution is needed, or the architecture already wants the cap lines. Mixed solutions with horizontal caps and vertical silicone (or the reverse) are also common.
When to choose structural silicone?
When a continuous, flush glass look is wanted and there is a fabricator able to manage the quality control process. The silicone bite is calculated from wind suction; tall buildings or some regulations may require an additional mechanical safety device. Application and testing of siliconed frames follow ETAG 002 / EN 15434.
Questions to ask
- Will glass be replaced from inside or outside, and is there façade access?
- How wide does the silicone bite come out for the wind load and pane size?
- Does the fabricator have silicone compatibility and adhesion test records?
This guide is for education and preliminary information only; regulations, standards and values may change. Consult a qualified engineer before making decisions. If you spot an error, let me know. · All guides