- ΔL = α · L · ΔT; aluminium expands about twice as much as steel.
- Joint width = total movement divided by the sealant's movement capability.
- Depth is usually half the width (2:1), with a backer rod behind.
Expansion coefficients
| Material | α (1/K) | ΔL for 3 m, 50 K |
|---|---|---|
| Aluminium | 23–24 × 10⁻⁶ | ≈ 3.5 mm |
| Steel | 12 × 10⁻⁶ | ≈ 1.8 mm |
| Stainless (austenitic) | 16 × 10⁻⁶ | ≈ 2.4 mm |
| Glass | 9 × 10⁻⁶ | ≈ 1.4 mm |
| Concrete | 10–12 × 10⁻⁶ | ≈ 1.7 mm |
Temperature range
The calculation uses the difference between the installation temperature and the extreme temperatures. Dark, sun-exposed metal surfaces can reach 70–80 °C in summer and drop below −10 °C in winter, so design ranges of ±40 K and more are common on façades.
Joint width
With a ±25% sealant, 3.5 mm of movement needs a joint of at least 14 mm; adding manufacturing and installation tolerances, 15–20 mm is chosen. The movement capability is on the sealant data sheet (ISO 11600 class, e.g. 25LM).
Depth and backer rod
Sealant depth should be about half the width (at least 6 mm); a sealant that is too deep restricts movement. A closed-cell backer rod is placed behind it, and the sealant should bond to two sides only; three-sided adhesion causes cracking.
This guide is for education and preliminary information only; regulations, standards and values may change. Consult a qualified engineer before making decisions. If you spot an error, let me know. · All guides