Double Skin Facades
When is a double skin facade needed, which type should you choose, how is the cavity ventilated? Seven days covering solar control, wind, acoustics, fire and maintenance.
Before you start
Who is it for
Facade designers, architects and facade consultants working on tall and high-profile buildings.
What you need
- Basic facade systems and facade physics (Facade Physics, in Turkish)
Programme
| Day | Topic | What you learn | Time |
|---|---|---|---|
| Day 1 | Definition and types | Benefits, drawbacks, four basic types, CCF | ~3.5 h |
| Day 2 | Ventilation | Natural, mechanical, hybrid; airflow paths; stack effect | ~3.5 h |
| Day 3 | Sun | Blind position, glass selection, cavity temperature | ~3.5 h |
| Day 4 | Structure and physics | Wind load, acoustics, condensation, brackets and walkways | ~3.5 h |
| Day 5 | Fire | Smoke spread, risk by type, measures | ~3.5 h |
| Day 6 | Maintenance and CCF | Cleaning four faces, unitized double skin, closed cavity | ~3.5 h |
| Day 7 | Decision | Is it needed, choosing the type, checklist, final exercise | ~3.5 h |
Each day ends with a checklist. Your ticks are saved in this browser. If you only study on weekday evenings, the course takes about two weeks. Example figures are for teaching; every project needs energy, airflow (CFD) and fire analysis.
Definition and types
Goal
By the end of the day you will know what a double skin facade is, why and when it is used, its drawbacks and its basic types. About 3 hours.
About this course: types, ventilation, solar control, fire, acoustics and maintenance of double skin facades (DSF) from a facade designer's point of view. Basic facade physics: Facade Physics (in Turkish); thermal calculation: Thermal Calculation. Example figures are for teaching; every project needs energy and airflow (CFD) analysis. Terms are in the glossary.
1. Definition (30 min)
A double skin facade adds a second skin, usually of glass, in front of (or behind) an ordinary facade. Between the two skins there is a ventilated cavity; its depth ranges from a few centimetres to 2 metres. If the cavity is not ventilated, it is just a very thick window.
| Skin | Typical |
|---|---|
| Outer skin | Single glass, tempered or laminated; takes wind and rain |
| Cavity | Blinds, airflow, maintenance walkway |
| Inner skin | Curtain wall with insulating glass, opening vents |
2. Why? (45 min)
| Benefit | Explanation |
|---|---|
| Solar control | Blinds in the cavity are protected from wind and dirt; they catch heat in the cavity before it enters |
| Natural ventilation | Windows can be opened even in tall buildings (the outer skin cuts the wind) |
| Acoustics | Reduces outside noise in noisy places, even with windows open |
| Thermal buffer | In winter the cavity is warmer than outside |
| Appearance | A uniform, all-glass outer surface |
3. Drawbacks (45 min)
| Drawback | Explanation |
|---|---|
| Cost | Two skins, cavity equipment, more maintenance |
| Overheating | A poorly ventilated cavity can become an oven in summer |
| Fire and smoke | The cavity can become a channel for smoke between floors (day 5) |
| Cleaning | Four glass surfaces to clean (day 6) |
| Lost floor area | The facade depth takes lettable area |
Rule: a double skin only makes sense if at least one of the benefits above is really needed in the project.
4. Types (45 min)
| Type | Cavity division | Note |
|---|---|---|
| Box window | Each window is a separate box; divided at floors and sides | Best acoustic and fire separation |
| Shaft-box | Box windows open into vertical shafts running several floors | Ventilation by stack effect |
| Corridor | Continuous horizontal corridor on each floor, divided between floors | Mid-rise offices |
| Multi-storey | Cavity continuous over many floors | Strong stack effect; weak for fire and acoustics |
In addition there is the closed cavity facade (CCF): the cavity is closed to the outside and supplied with dry, clean air; it is produced as unitized modules (day 6).
End-of-day check (15 min)
Ventilation
Goal
By the end of the day you will know the cavity ventilation modes (natural, mechanical, hybrid), the airflow paths and the size of the stack effect. About 3 hours.
1. Ventilation modes (45 min)
| Mode | How the air moves |
|---|---|
| Natural | Stack effect (warm air rises) and wind pressure |
| Mechanical | Fans and the building ventilation system |
| Hybrid | Natural first, fan-assisted when needed |
2. Airflow paths (1 hour)
| Path | Air from → to | When |
|---|---|---|
| Outdoor air curtain | Enters from outside, passes the cavity, leaves outside | Summer: remove heat from the cavity |
| Indoor air curtain | Enters from inside, passes the cavity, returns inside or to the extract | Winter: warm the inner skin surface |
| Supply | From outside into the cavity, then inside | Preheated fresh air |
| Exhaust | From inside into the cavity, then outside | Remove used air |
| Buffer | Cavity closed | Winter, night |
The airflow path can be switched with dampers; an operating scenario is written for each season.
3. Stack effect (45 min)
The pressure difference produced by the stack effect is roughly:
ΔP ≈ ρ · g · h · (ΔT / T)
Example: h = 12 m (four floors), cavity 10 K warmer than outside, T ≈ 300 K, ρ = 1.2 kg/m³:
ΔP ≈ 1.2 × 9.81 × 12 × (10 / 300) ≈ 4.7 Pa
That is a very small pressure: wind pressures can be tens or hundreds of pascals. So the size of the openings and the effect of wind can only be assessed reliably with an airflow (CFD) or building energy simulation.
4. Openings (15 min)
- If inlet and outlet openings are stacked directly above each other, one floor's exhaust mixes into the next floor's inlet (short circuit). Stagger the openings or use deflectors.
- Openings must be protected against rain, snow and insects (louvres, grilles).
End-of-day check (15 min)
Sun
Goal
By the end of the day you will know how blinds in the cavity, glass selection and cavity temperature affect facade performance. About 3 hours.
1. Where the blinds go (1 hour)
| Position | Advantage | Disadvantage |
|---|---|---|
| Outside | Cuts heat best | Wind, dirt, maintenance; difficult on tall buildings |
| In the cavity | Protected; leaves heat in the cavity to be ventilated away | Cavity heats up; ventilation is essential |
| Inside | Cheap, easy | The heat is already inside |
The position of the blind in the cavity also matters: a blind close to the outer skin keeps the heated air away from the inner skin and makes it easier to exhaust.
2. Glass selection (45 min)
| Skin | Typical glass | Why |
|---|---|---|
| Outer | Single glass, tempered or laminated; can be low-iron | Wind and impact; let solar radiation into the cavity |
| Inner | Insulating glass, low-e | Thermal insulation (U-value) |
A solar control coating on the outer skin reduces cavity overheating but changes light and appearance. The total solar energy transmittance (g) of the system changes with the blind position; calculate it separately for blinds up and down.
3. Cavity temperature (45 min)
- In summer a poorly ventilated cavity can be much hotter than outside; the inner skin surface heats up and comfort suffers.
- In multi-storey types the upper floors are hotter (warm air rises).
- In winter the cavity works as a buffer; heat loss through the inner skin drops.
The design should check the cavity temperature for the hottest day (worst case) by simulation.
4. Daylight and view (15 min)
Two skins, blinds and coatings reduce light transmittance. Reflections and double images (between two glass surfaces) should be considered in the architectural approval.
End-of-day check (15 min)
Structure and physics
Goal
By the end of the day you will know about wind load, acoustics, condensation, drainage and the supporting structure (brackets, walkways) of double skin facades. About 3 hours.
1. Wind load (45 min)
- The outer skin takes the wind load; it is designed for the full design load.
- The load on the inner skin depends on the cavity openings: with large openings the cavity pressure approaches the outside pressure and the inner skin also takes a significant load.
- Open and closed (dampers) conditions are assessed separately. For tall buildings wind tunnel data are used (Structural Basics, in Turkish).
2. Acoustics (45 min)
- The outer skin reduces noise through an open window; this is one of the strongest reasons for a double skin.
- Room to room sound: in corridor and multi-storey types sound can travel through the cavity to the next room and floor. The box window type is the best here.
- Ventilation openings are acoustic weak points; acoustic (attenuated) louvres can be used.
3. Condensation and water (45 min)
- In winter the outer skin is cold; if moist air leaks from inside into the cavity, it condenses on the inner face of the outer skin.
- Prevention: make the inner skin airtight; ventilate the cavity with outside air (which is cold and dry).
- Rain, snow and condensate entering the cavity need a sloped floor and drainage.
4. Structure and walkways (45 min)
- The outer skin is carried by brackets projecting from the slabs (steel or aluminium); brackets are thermal bridges, use thermal break pads.
- A maintenance walkway on each floor: grating floor you can walk on for cleaning and maintenance. Grating lets air through but must be assessed for fire and smoke (day 5).
- Walkway loads (people, equipment) and guardrails must be part of the design.
End-of-day check (15 min)
Fire
Goal
By the end of the day you will know the fire and smoke spread risk in double skin facades, how the types differ and what measures are taken. About 3 hours.
1. Risk (1 hour)
If a window breaks in a fire, hot gases and smoke enter the cavity. If the cavity is vertically continuous (multi-storey and shaft types), it works like a chimney and carries smoke and heat to the floors above. The outer skin also reflects heat back and heats the cavity further.
| Type | Vertical spread risk |
|---|---|
| Box window | Low (each floor and window divided) |
| Corridor | Low-medium (divided between floors; watch the opening layout) |
| Shaft-box | High (shafts vertically continuous) |
| Multi-storey | High |
2. Measures (1 hour)
- Division between floors: fire-resistant horizontal barriers at each floor (or every few floors).
- Opening layout: one floor's outlet must not sit directly below the next floor's inlet.
- Dampers: dampers that close or open automatically in a fire (depending on the smoke strategy).
- Sprinklers: in some projects, in the cavity or in front of the inner skin.
- Materials: fire classes of blinds and other materials in the cavity.
3. Regulations and analysis (45 min)
- National fire regulations (in Turkey: the Regulation on Fire Protection of Buildings; see Fire Regulation, in Turkish) may not describe double skins in every detail; a fire strategy is prepared with a fire consultant.
- CFD fire and smoke simulation (e.g. with FDS) shows the effect of the design; research shows that cavity depth and opening geometry clearly affect smoke movement.
End-of-day check (15 min)
Maintenance and CCF
Goal
By the end of the day you will know the maintenance and cleaning needs of double skin facades, unitized double skins and the closed cavity facade (CCF). About 3 hours.
1. Cleaning (45 min)
A double skin has four glass surfaces to clean: both faces of the outer skin and both faces of the inner skin. For the two faces in the cavity:
- A maintenance walkway on each floor (day 4), or
- Inner vents opening into the cavity, or
- Openable panels in the outer skin.
Cleaning frequency and method must be decided in the design; without access the cavity faces are never cleaned (Facade Maintenance and Access, in Turkish).
2. Maintenance of cavity equipment (30 min)
Blind motors, dampers, sensors and cables are in the cavity: plan access, spare parts and how to replace a failed unit.
3. Unitized double skin (45 min)
A double skin can also be factory-made as unitized modules: inner and outer skins, blinds and cavity come in one module. Advantages: factory quality, fast installation, a thinner facade (less lost area). Module joints and the continuity of the cavity between modules must be solved in the design (Facade Installation, in Turkish).
4. Closed cavity facade (CCF) (45 min)
| Feature | CCF |
|---|---|
| Cavity | Closed to the outside |
| Air | A small continuous supply of dry, filtered air to the cavity (slight overpressure) |
| Purpose | No condensation or dust; no cleaning inside the cavity |
| Blinds | In the cavity, protected |
| Watch out | Continuity and maintenance of the air supply; airtightness |
Unlike a ventilated double skin, a CCF does not remove cavity heat with airflow; summer heating is controlled by the blinds, glass coatings and design. Thermal and condensation calculations must therefore be detailed.
End-of-day check (15 min)
Decision
Goal
On the last day you will decide on a double skin for a project, choose the type, prepare the design checklist and complete the final exercise. About 3.5 hours.
1. Decision: is it really needed? (45 min)
| Question | If yes |
|---|---|
| Is the site very noisy and should windows open? | Strong candidate |
| Is the building tall and is natural ventilation wanted? | Candidate |
| Is external solar shading difficult (wind, maintenance)? | Candidate |
| Are the budget and the lost area acceptable? | Continue |
| Can the fire strategy be solved? | Continue |
If the answer to all is "no", a well-designed single skin with external shading is usually more economical (Solar Shading, in Turkish).
2. Choosing the type (45 min)
| Priority | Suitable type |
|---|---|
| Acoustic and fire separation | Box window |
| Natural ventilation, mid-rise | Corridor |
| Strong stack effect, few openings | Shaft-box |
| Uninterrupted appearance | Multi-storey (with fire measures) |
| Low maintenance, clean cavity | CCF |
3. Design checklist (1 hour)
4. Final exercise (45 min)
For a 12-storey office building facing a noisy street: